Daily maintenance and common faults of lifting columns

Routine maintenance
1. Avoid continuous rise or fall during use. Rise and fall should not be switched quickly and continuously, which will easily shorten the service life of the motor and hydraulic pump.
2. Check the oil level in the fuel tank regularly. If the oil level is lower than the bottom line, you need to add oil. If the oil color becomes dark and turbid, you need to consider replacing the oil.
3. It is strictly forbidden to raise if there is a vehicle or pedestrian above the road pile to avoid danger.
4. Keep the bottom of the pile on the hoistway clear and clean around, to ensure the service life and performance of the lifting pile parts and waterproof sealing.
5. On large ice and snow days, if there is severe icing inside the column, lifting is prohibited. It can be used after thawing by heating.
common problem
Hand pressing the control panel button has no action
Causes: 1. The power supply line is faulty.
2, the fuse is blown
3, motor failure
Processing method: 1. Check if the AC220V power supply is normal.
2, replace the same type of fuse
3. Replace the starting capacitor or repair the motor
The column cannot rise or rise very slowly
Reasons: 1. The oil supply system is not smooth.
2. The pressure relief valve is not closed tightly.
3, overflow cutting over pine
Treatment method: 1. Check the oil pipe to ensure that it does not gamble.
2, close the pressure relief valve
3, fine-tuning the relief valve
The cylinder drops very slowly:
Reasons: 1. The oil supply system is not smooth.
2. The relief valve is too tight or too loose
Treatment method: 1. Check the oil pipe to ensure that it does not gamble.
2, fine-tuning the relief valve
The cylinder has a straight drop
Reasons: 1. Manual pressure relief valve is too loose
2, hydraulic oil leakage
3, hydraulic lock failure
Treatment method: 1. Close the pressure relief valve
2, eliminate leakage, add hydraulic oil
3, replace the hydraulic lock

Snoworld Common Ice Storage has several features.

 

1. Easy to install, time saving and low maintenance free.

2. High quality refrigeration system is install to keep the room temperature within the range of -5 to -7 C degree, which guarantees no ice melting.

3. Stainless steel surface and color steel surface are supplied for customer to choose. 100mm high density polyurethane foaming inside.

4. Customized design is acceptable.

 

Common Ice Storage

Commercial Ice Bin,Color Steel Ice Storage,Ice Storage With Freezer,Low Temperature Ice Storage

Fujian Snowman Trade Co., Ltd. , https://www.sinoicemachine.com