Sweeper Parts Bmer-300-Wst4rb Cycloid Hydraulic Oil Motor Replace Parker Tg Series

Model NO.: BMER
Feature 2: Euro Brand Danfoss, M+S, Eaton and Others
Feature 3: Stable Quality
Feature 4: Customize Service Provided
Quality: N (AA), G (AAA)
Trademark: HANJIU
Transport Package: 1 PC/ Inner Carton, 3 PCS/ Outer Carton
Specification: 27x40x14cm
Origin: China
HS Code: 8412291000

Sweeper Parts BMER-300-WST4RB Cycloid Hydraulic Oil Motor Replace Parker TG Series


Hanjiu BMER-300-WST4RB Cycloid Hydraulic Oil Motor Replaces Parker TG Series


Features:
 
(1) Compact size, high efficiency
 
(2) Low-friction and long life advantages
 
(3) Internal check valves, Escort seal
 
(4) This motor has a rugged housing with an extra large capacity side load bearing
 
(5) Shaft seal can bear high pressure of back and the motor can be used in parallel or series
 
(6) Geroler and drive use the SMT series motors parameter, prolong operating life.
 
 
Specification:
 
Model: BMER1-200-WS-T4-S
Disp. 11.96 cu.in./rev.
Pressure:
2973 PSI(Cont.)
3481 PSI(Int.)
Torque
4691 in-lb. (Cont.)
6310 in-lb. (Int.)
Speed
330 PRM (Cont.)
425 RPM (Int.)
Flow
18.5 GPM (Cont.)
22.4 GPM (Int.)
Rotation Reversible
Mount 4 Bolt Wheel
5.812 bolt circle, 3-1/4" pilot dia
Shaft 1-1/4" tapered*4.21"
shaft w/5/16" key and threaded end
Ports SAE 10
Size 4.94"*5.25"*5.45"
Shpg. 30lbs.
 
YPE    BMSW-315    BMSW-400    BMSW-500    BMSW-630    BMSW-800    BMSW-985
Displacement(ml/r)    314.9    399.7    496.6    617.8    787.4    969.1

Max.Pressure.Drop(Mpa)    cont.    20    20    20    18    16    14
int.    24    24    24    21    18    16
peak.    28    28    28    24    21    18
Max.Torque(N.m)    cont.    873    1108    1385    1570    1773    1900
int.    1119    1440    1783    1951    2122    2133
peak.    1293    1650    2060    2249    2481    2399
Speed.Range(cont.)(r/min)    10-475    9-375    8-300    6-238    5-187    5-154
Max.Flow(cont.)(L/min)    150    150    150    150    150    150
Max.Output.Power(cont.)(Kw)    32    32    32    32    32    24
Weight(kg)    30.7    31.5    32.4    33.6    35.2    37.2
Sweeper Parts Bmer-300-Wst4rb Cycloid Hydraulic Oil Motor Replace Parker Tg Series

Sweeper Parts Bmer-300-Wst4rb Cycloid Hydraulic Oil Motor Replace Parker Tg Series
Sweeper Parts Bmer-300-Wst4rb Cycloid Hydraulic Oil Motor Replace Parker Tg Series

Product application
Sweeper Parts Bmer-300-Wst4rb Cycloid Hydraulic Oil Motor Replace Parker Tg Series





Shijiazhuang HanJiu technology co., LTD., is specialized in the production of BM series cycloid hydraulic motor, the BZZ redirector enterprise, my factory has dozens of high-quality, professional engineering and technical personnel, and more than in 2010, has introduced the most advanced production equipment, is in northern China's largest factories, production of more than 300000 units a year.
My factory specializes in designing and producing the motors and steering gear of any type, from large to small, from low to high, and so on. And can replace danfoss, Eaton, M+S series models. Products are widely used in engineering machinery, mining machinery, metallurgical machinery, petroleum machinery, agricultural machinery, injection molding machinery, fishery machinery, military engineering and other fields.
My factory take the good faith first, quality first for the purpose, from the employee on-boarding, raw materials into the factory, from parts processing, assembly proposal until products, has a relatively perfect system of product quality. And through CE certification. Our factory is dedicated to the establishment of an internationally renowned brand, looking forward to the long-term cooperation with more demand of hydraulic products.
Sweeper Parts Bmer-300-Wst4rb Cycloid Hydraulic Oil Motor Replace Parker Tg Series




Please do not hesitate to contact us for further information, inquiries or orders.

Thank you for choosing 'Hanjiu' Hydraulics.




Sweeper Parts Bmer-300-Wst4rb Cycloid Hydraulic Oil Motor Replace Parker Tg Series

 

1, What is cold room?

Cold room is a building warehouse using refrigeration machine Cold Room Units to reach a certain temperature and has insulation to hold the temperature.
It is also a constant temperature and humidity storage room for foods, liquid, chemical, pharmaceutical, vaccine, scientific experiments and other items. The refrigeration system of the cold room is still a core component of the construction of the entire Cold Storage Room.
2, Cold room classification:
According to the structure
â—‡ Civil engineering cold room building
â—‡ Steel structure cold room
â—‡ Mixed structure
Mobile Cold Room , Modular Cold Room and Cold Room Container.
According to the cold room usage
â—‡ Production type cold room used in food, meat, fish factory
â—‡ Distribution type cold room used for logistics
â—‡ Retail cold room used for supermarket
â—‡ Household cold room
According to the cold room scale
â—‡ Large Cold Storage over 10,000 tons
â—‡ Medium-sized cold storage 1000-10,000 tons
â—‡ Small cold storage less than 1000 tons
According to the cold room temperature
◇ High temperature Cold Room Chiller room design temperature (-2~8°C)
◇ Medium temperature cold room design temperature (-10~-23°C)
◇ Low temperature Cold Room Freezer Room design temperature (-23~-30°C)
◇ Ultra-low temperature cold room design temperature (-30~-80°C)
According to the cold room goods
â—‡ Seafood and meat cold room
â—‡ Dairy and ice cream cold room
â—‡ Fruit and vegetables cold room
â—‡ Pharmaceutical and chemicals cold room
â—‡ Flower cold storage
3, Cold room refrigerant choice
â—‡Ammonia: the oldest in history, the best choice in the field of industrial refrigeration worldwide. Due to the characteristics of the ammonia system, it is generally used for centralized refrigeration, with a special machine room for large-scale refrigeration systems (more than 10,000 tons of cold storage). There is a trend toward miniaturization and modulation, with an emphasis on improving safety and reducing the amount of charging.
â—‡ Freon: It is widely used in cold storage to disperse refrigeration. It is suitable for small and medium-sized cold storage and large-scale cold storage with limited ammonia. For environmental protection, large-scale cold storage The Freon system should be avoided as much as possible.
â—‡ CO2: The cold storage application is mainly based on cascade system and loading system. The low-temperature field is more suitable for cascade. The high-temperature field is suitable for loading. The cascade system is more expensive than the traditional ammonia and Freon system.
4, Cold room defrosting ways
Hot-gas defrosting
Water defrosting
Electricity defrosting

How is a cold room designed?
A good design of these rooms considers not only the selection of equipment, but its location for a safe access of the personnel. To ensure a safe access and maneuver into the cold room, it is necessary that contractors, engineers and owners participate in the project to determine the selection of a cooling system determined by analyzing life cycle cost and energy efficiency.
As your cold room expert, more than 18 years refrigeration experience, from design to installation and maintenance service, we provide one stop cold storage service for your fresh life. Best practice for building cold storage and controlling energy saving. We are China leading manufacturers and suppliers of Cold Room Units, Freezer Room and Mobile Cold Room, and we are specialize in Modular Cold Room,Cold Room Container, etc.


Cold Rooms

Cold Room Units,Freezer Room,Mobile Cold Room,Modular Cold Room,Cold Room Container

Shandong Atlas Refrigeration Technology Co.,Ltd. , https://www.atlascoldroom.com