Cooling System Water Chiller for Research Laboratory
Our Products Include:
3kw ~ 3000kw / Outlet temperature: 7ºC ~ -85ºC /
Air-cooled, water-cooled, screw type, scroll type, heat pump chiller, modular chiller.

The Details of the Chiller:
1. Temperature Range: 7ºC to -85ºC
2. Cooling Capacity Range:
1RT to 1000RT
52kW to 3520kW
12010Btu to 12010240Btu
3027.2Kcal to 3027200Kcal
3. Refrigerant: R22/R407C/R410A/R404A/R134A/R507C
4. Customization Available Based on Your Needs
One Parameter of Our Water Chiller:
Model | WD- | ||||||||||||||||||||||||
UNIT | 188.1WSM3 | 220.1WSM3 | 235.1WSM3 | 260.1WSM3 | 260.1WSM3 | 290.1WSM3 | 335.1WSM3 | 372.1WSM3 | 400.1WSM3 | 445.1WSM3 | |||||||||||||||
Cooling Capacity | Btu | 641456.00 | 750640.00 | 801820.00 | 887120.00 | 955360.00 | 989480.00 | 1143020.00 | 1269264.00 | 1364800.00 | 1518340 | ||||||||||||||
RT | 53.41 | 62.50 | 66.76 | 73.86 | 79.55 | 82.39 | 95.17 | 105.68 | 113.64 | 126.42 | |||||||||||||||
kW | 188.00 | 220.00 | 235.00 | 260.00 | 280.00 | 290.00 | 335.00 | 372.00 | 400.00 | 445.00 | |||||||||||||||
×10â´Kcal/h | 16.00 | 19.00 | 20.00 | 22.00 | 24.00 | 25.00 | 29.00 | 32.00 | 34.00 | 38.00 | |||||||||||||||
Control Mode | PLC Automatic Control | ||||||||||||||||||||||||
Power Source | 380V/3N/50HZ | ||||||||||||||||||||||||
Compressor | Type | 5-6 Asymmetric Semi-Hermetic Twin Screw Compressors | |||||||||||||||||||||||
Startup Type | Y-â–³ | ||||||||||||||||||||||||
Energy Regulation | 0-12.5%-25%-37.5%-50%-62.5%-75%-87.5%-100% | ||||||||||||||||||||||||
Qty | 1 | ||||||||||||||||||||||||
Input Power | kW | 81.70 | 94.90 | 100.20 | 108.50 | 116.80 | 120.60 | 141.70 | 157.20 | 166.90 | 184.00 | ||||||||||||||
Operation Current | A | 142.20 | 165.10 | 174.30 | 188.80 | 203.20 | 209.80 | 246.60 | 273.50 | 290.40 | 320.20 | ||||||||||||||
Condenser | Type | High Efficiency Copper Dry Shell-and-Tube Heat Exchanger | |||||||||||||||||||||||
Water Pipe Connection | Â | DN100 | DN125 | DN150 | |||||||||||||||||||||
Cooling Water Flow | m³/h | 61.30 | 71.50 | 76.20 | 83.70 | 90.20 | 93.30 | 108.30 | 120.20 | 128.80 | 142.90 | ||||||||||||||
Water Pressure | kPa | 58.00 | 58.00 | 65.00 | 70.00 | 70.00 | 71.00 | 71.00 | 72.00 | 72.00 | 72.00 | ||||||||||||||
Evaporator | Type | Horizontal Shell-and-Tube / Coil Type High Efficiency Copper Heat Exchanger | |||||||||||||||||||||||
Water Pipe Connection | Â | DN80 | DN100 | DN125 | |||||||||||||||||||||
Freezing Water Flow | m³/h | 40.00 | 47.50 | 50.00 | 55.00 | 60.00 | 62.50 | 72.50 | 80.00 | 85.00 | 95.00 | ||||||||||||||
Water Pressure | kPa | 58.00 | 58.00 | 67.00 | 72.00 | 72.00 | 72.00 | 72.00 | 72.00 | 72.00 | 73.00 | ||||||||||||||
Refrigerant | Type | R22 | |||||||||||||||||||||||
Kilogram | kg | 64.00 | 75.00 | 80.00 | 89.00 | 96.00 | 99.00 | 114.00 | 127.00 | 136.00 | 152.00 | ||||||||||||||
Safety Protection | High and low pressure protection; over temperature protection; overload protection; phase sequence protection, etc. | ||||||||||||||||||||||||
Dimensions (L*W*H) | Length | mm | 3225 | 3225 | 3225 | 3505 | 3605 | 3605 | 3720 | 3720 | 3720 | 3930 | |||||||||||||
Width | mm | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | ||||||||||||||
Height | mm | 1830 | 1830 | 1880 | 1880 | 1950 | 1980 | 1880 | 1950 | 1970 | 2020 | ||||||||||||||
Net Weight | kg | 1970 | 2190 | 2440 | 2480 | 2650 | 2950 | 3080 | 3300 | 3470 | 3620 | ||||||||||||||
Operating Weight | kg | 2190 | 3380 | 2570 | 2740 | 2950 | 3210 | 3330 | 3570 | 3810 | 3930 |
Note:
1. Freezing water inlet temperature: -10°C, outlet temperature: -15°C; cooling water inlet temperature: 30°C, outlet temperature: 35°C;
2. Temperature conditions: Freezing water outlet range: 5°C–15°C; cooling water inlet range: 19–33°C;
3. Safe operating range: Freezing water inlet temperature: 9°C–20°C;
4. The compressor is imported from Europe and the US, with superior performance and strong anti-fouling ability;
5. Nominal operating conditions: Evaporator and condenser fouling factor: 0.018 m²·°C/kW; condenser fouling factor: 0.044 m²·°C/kW;
6. The evaporator and condenser are designed to withstand a pressure of 1.0MPa;
7. The actual head of the host is the pump head minus the losses within the host;
8. In addition to the specifications, we can provide non-standard products according to customer requirements.
Company Profile:
Winday Industrial is a professional company engaged in R&D, manufacturing, and sales of industrial refrigeration equipment and refrigeration system design and installation services.
We take product quality and performance seriously, focusing on "efficiency, stability, and energy efficiency progress."
Our manufacturing process ensures excellence, strict control, and thorough examination.
In refrigeration system design, we conduct repeated research, experiments, scrutiny, and feasibility studies to provide customers with optimized cooling system integration solutions and high-quality equipment.
Contact Us:
Seamless carbon steel pipes are made of steel ingots or solid billets through perforation to make capillaries, which are then hot-rolled, cold-rolled or cold-drawn. The raw material of carbon Steel Pipe is a round tube blank, which is cut by a cutting machine into a billet with a length of about 1 meter, and sent to a furnace for heating through a conveyor belt. The billets are fed into the furnace and heated at about 1200 degrees Celsius. The fuel is hydrogen or acetylene. Furnace temperature control is a critical issue. After the round tube blank is released from the furnace, it is pierced through a pressure punching machine. Generally, the more common punching machine is the conical roller punching machine. This kind of punching machine has high production efficiency, good product quality, large amount of perforation and diameter expansion, and can wear a variety of steel grades. After perforation, the round tube blank is successively cross-rolled, continuously rolled or extruded by three rolls.
1. Seamless steel pipe for structure (GBT8162-2008). Mainly used for general structure and mechanical structure. Its representative material (brand): carbon steel, 20, 45 steel; alloy steel Q345, 20Cr, 40Cr, 20CrMo, 30-35CrMo, 42CrMo, etc.
2. Seamless steel pipes for conveying fluids (GBT8163-2008). It is mainly used for conveying Fluid Steel Pipe in engineering and large-scale equipment. The representative material (grade) is 20, Q345, etc.
3. Seamless steel pipes for low and medium pressure boilers (GB3087-2008) are used to manufacture various structures of low and medium pressure boiler superheated steam pipes, boiling water pipes and superheated steam pipes, large smoke pipes, small smoke pipes and arch bricks for locomotive boilers Hot-rolled and cold-drawn (rolled) seamless steel pipes of high-quality carbon structural steel for pipes. The representative material is 10, 20 steel.
Carbon Steel Tube, Mild Steel Pipe, Hot Rolled Steel Pipe, Weld Steel Pipe
Shandong Guanzhou Iron and Steel Group Co., Ltd. , https://www.guanzhousteel.com