HXPnR-H single-stage safety trolley line power supply and installation and maintenance instructions

Power supply <br> <br> considered safe wire feeding points should be considered simultaneously with the electrical equipment of the trolley line across the total capacity of the total number of units, the voltage drop across the board and the mandate of the working length of the system, and environmental (voltage The drop calculation can be calculated based on the data of the front rail parameter table). Power supply generally has the following types for users' reference: 1 Single-ended power supply: 2 Central power supply: 4 Both ends of the power supply 4 Both ends 1/6 power supply; 5 Both ends of the 1/10 and the central three power supply. Installation and maintenance instructions <br> <br> installation instructions

Before installing the trolley wire, firstly install the angle bracket according to the user's choice of installation type. According to the suspension of the trolley wire, fix it and fix it on the installation site to put the desired suspension bracket on the 6-meter-long sliding wire. , And one end of the two joints jacket, one end is equipped with an aluminum joint, when installing aluminum joints, it should be noted that only the aluminum guide into the joint 1/2 left to connect the other rail, after the above work is ready , And then one by one to hang on the bracket on the wire, for full-line connection, the connection should be tightened each connector screw. When the total length of the trolley line exceeds 200 meters, a telescopic device (telescometer provided by the factory) shall be installed. When the power cable is connected to the line, it may be connected at a joint of every 6 meters. The specific connection method can refer to the front Connector device diagram.

When installing a curved trolley line, the suspension distance should be shortened accordingly. The specific dimensions can be determined according to site conditions.

When installing the conductive device, the conductive device is first installed on the matching square tube, and the appropriate position matched with the trolley line is selected to be fixed on the electrical equipment. Care should be taken to ensure that the conductive device and the trolley line have good tracking performance. For good contact pressure, the conductor and trolley wire should be installed in the same vertical and horizontal direction.

Industrial check valves are wildly used in all type of industrial pipelines, such as power stataion, petrochemical, natual gas,water treatment ect. Swing Check Valve, Wafer Check Valve, titling Disc Check Valve , Piston Check Valve, disc checkvalve, Lift Check Valve and Api 602 Check Valve with ASME & DIN & EN & GOST standard are commonly used by customer. Industrial check valve we provided can cover size from 1/2 inch to 48 inch(DN15-DN1200) matching pressure from class 150 to class 2500(PN10-PN420) which are suitable for operating in the working media temperature from -196℃ to 693℃, as well as material in carbon steel, stainless steel, alloy steel and duplex steel in casting material or forging material.

Check Valve

Check Valve,Piston Check Valve,Pvc Check Valve,Check Disc Valve

Yongjia South Trading Co.,Ltd , https://www.n-lvalve.com