The human body tester with access control system should have the function

Today, with advanced technology, the electronic industry is increasingly demanding static electricity, especially for the human body that is most vulnerable to static electricity, and electrostatic protection is becoming increasingly strict. Many factories install humans with access control systems at the entrance to the production hall. Comprehensive tester, now to introduce the human body integrated tester with access control system:
Electrostatic protection access control system is a set of computerized anti-static test access control management system, software and hardware equipment, can be a stand-alone. Local connection. TCP / IP communication connection. The access control system can store all incoming and outgoing records, status records. RS485 interface is used to connect with the computer. The system uses non-contact ID card technology, uses RF signals to exchange data, avoids contact, has high security, high reliability, and monitors employees' anti-static requirements in real time.
The gateless machine will not restrict the entry and exit of personnel. In the case that employee data has been saved, if an employee who has not been swiped card can check in the corresponding item in the software, the credit card record can be used as an attendance record, and the user needs to swipe for static electricity testing. Just come out and swipe. In the computer, you can view the time of entering and exiting the card for all personnel, automatically recognize the employee's authority, and conduct a complete test within 5 seconds, which is convenient and quick.
I. Standard Operating Procedures for Electrostatically Protected Access Control Systems:
1. The tester wears anti-static shoes or hamstrings to step on the footboard of the tester.
2. Insert the ESD wrist strap into the tester. The tester wears the wrist strap.
3. Place the ID/IC card on the body near the card reader and read the information on the card.
4. Press and hold the tester button on the tester and wait for the LED on the tester to display the test results.
5. If the test is OK, the wristband and hamstrings are displayed with PASS (LED indicates green light). You can directly enter the production area. The test results of the test staff will be automatically recorded on the computer. The results are displayed in the green font static test.
6. If the test result is not OK, check the tester's wrist strap and anti-static shoes (or hamstring tape) according to the LED display of the tester. The test results of the test employee will be automatically recorded on the computer. Whether or not it can be accessed directly or through, relevant managers need to check the corresponding test results to replace or detect wrist straps or work shoes of unqualified personnel.
II. Installation and Test
Independently selectable for use with air shower/tri-roller/suspension box
The following is a mounted ticket box installation method:
1. Select the area where the machine needs to be installed, and fix the device after punching holes in the wall.
2. Fix the test pedal in front of the device and connect the pedal to the left and right feet of the instrument head with a cable.
3. The equipment is equipped with a 220V power supply.
4. Insert the instrument's power plug into the power jack on the left side of the meter.
Connect the control board to the power supply.
5. Connect the device power supply.
6. Connect the device to your computer with a network cable.
7. Start the software installation. For details, see "Electrostatic Protection Door System Software Operation Instructions".