US HPLC six-way valve injector use and maintenance instructions

The six-way valve injector is a crucial component in high-performance liquid chromatography (HPLC) systems, known for its reliability and precision. It consists of two main parts: a rotating seal called the rotor and a stationary base known as the stator. Among various models, the Rheodyne six-way valve injector stands out as one of the most versatile and widely used injectors across major HPLC manufacturers. How it works: When the handle is set to the "Load" position, the sample is introduced into the metering loop via an injection port using a micro-syringe. Once the loop is filled, any excess sample is expelled through an overflow port. Then, by turning the handle to the "Inject" position, the valve connects to the mobile phase flow path. The pump then flushes the loop with the mobile phase, carrying the sample into the analytical column for separation and analysis. Despite its simple design, the six-way valve injector offers long-term durability, ease of use, and minimal maintenance. However, proper handling and regular upkeep can significantly extend its lifespan, protect surrounding equipment, and improve analytical accuracy. With correct operation, the valve can perform over 30,000 injections without requiring maintenance. Here are some key tips for using and maintaining the six-way valve injector: 1. Avoid leaving the handle in the middle position between "Load" and "Inject." This can cause pressure surges in the system, potentially damaging the valve’s sealing components. Always move the handle quickly from one position to the other. 2. HPLC syringes differ from those used in gas chromatography—they are flat-head syringes. These needles are designed to fit tightly against the inner wall of the injector’s sealing tube, ensuring good sealing and preventing leaks or air bubbles. They also help avoid puncturing the stator or other internal parts. 3. There are two common injection methods: partial-loop and full-loop. In the partial-loop method, the injected volume can be up to 75% of the loop's capacity. For example, a 20 µL loop can take up to 15 µL of sample. Consistent and accurate volumes are essential for reproducibility. To ensure complete replacement of residual solution in the loop, the sample volume should be at least 3–5 times the loop size. So, for a 20 µL loop, you should inject at least 60–100 µL of sample. A 100 µL flat-head syringe is often recommended for full-loop injection. 4. Custom loops can be made based on the required injection volume. While exact volume calculations are not always necessary, consistency is key. For instance, a nominal 10 µL loop may actually hold 9 or 11 µL, but as long as the same volume is used for both standards and samples, the error will cancel out during data processing. 5. Sample preparation is critical. The sample must be free of particulates to prevent clogging or damage to the valve. Always filter the sample through a 0.45 µm membrane before injection. After each run, rinse the injector thoroughly with a salt-free diluent, water, or a buffer-free mobile phase to remove any residual salts or impurities that could accumulate and affect performance. Finally, always clean the outside of the syringe needle with lint-free paper after each use to maintain hygiene and prevent contamination. By following these guidelines, you can maximize the performance and longevity of your six-way valve injector.

Stacked Spiral Machine

Stacked Spiral Machine,Agricultural Screw Press,Sludge Dehydrator,Sludge Filter Press

Changzhou Senjie Environmental Protection Equipment Co., Ltd. , https://www.senjie-hb.com